{"id":295,"date":"2018-04-03T13:38:47","date_gmt":"2018-04-03T20:38:47","guid":{"rendered":"http:\/\/localhost\/kinetic\/?page_id=295"},"modified":"2026-11-20T06:57:52","modified_gmt":"2026-11-20T06:57:52","slug":"as1602","status":"publish","type":"page","link":"https:\/\/kinet-ic.com\/cn\/protection-system-monitoring\/emi-esd-suppression\/as1602\/","title":{"rendered":"AS1602 &lt;span class=&quot;&rdquo;redtext&rdquo;&quot;&gt;- Not Recommended For New Designs&lt;\/span&gt;"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"295\" class=\"elementor elementor-295\">\n\t\t\t\t<div class=\"elementor-element elementor-element-02e81e8 e-flex e-con-boxed section-light e-con e-parent\" data-id=\"02e81e8\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d29141 elementor-widget elementor-widget-text-editor\" data-id=\"6d29141\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div id=\"prod-button-list\">\n\t\t                        \n        <div style=\"clear: both;\"><\/div>\n    <\/div>\n     \t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f33681f product-tab elementor-widget elementor-widget-crafto-tabs\" data-id=\"f33681f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"crafto-tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t<div class=\"crafto-tabs tab-style-5\">\n\t\t\t\t<div class=\"crafto-container-wrap\">\t\t\t\t<ul class=\"nav nav-tabs alt-font\">\n\t\t\t\t\t\t\t\t\t\t\t\t<li class=\"elementor-repeater-item-1cde123 nav-item\">\n\t\t\t\t\t\t\t\t<a class=\"nav-link active\" data-bs-toggle=\"tab\" href=\"#tab-2550272311\">\n\t\t\t\t\t\t\t\t\t\u63cf\u8ff0\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<li class=\"elementor-repeater-item-94313d9 nav-item\">\n\t\t\t\t\t\t\t\t<a class=\"nav-link\" data-bs-toggle=\"tab\" href=\"#tab-2550272312\">\n\t\t\t\t\t\t\t\t\tFeatures\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<li class=\"elementor-repeater-item-a056022 nav-item\">\n\t\t\t\t\t\t\t\t<a class=\"nav-link\" data-bs-toggle=\"tab\" href=\"#tab-2550272313\">\n\t\t\t\t\t\t\t\t\t\u5e94\u7528\u7a0b\u5e8f\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<li class=\"elementor-repeater-item-8e6cdf7 nav-item\">\n\t\t\t\t\t\t\t\t<a class=\"nav-link\" data-bs-toggle=\"tab\" href=\"#tab-2550272314\">\n\t\t\t\t\t\t\t\t\tParameters\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t\t\t\t<\/ul>\n\t\t\t\t<\/div>\t\t\t<div class=\"tab-content\">\n\t\t\t\t\t\t\t\t\t\t<div id=\"tab-2550272311\" class=\"tab-pane fade in active show\">\n\t\t\t\t\t\t\t<p class=\"redtext\">This product is scheduled for End of Life and is therefore not recommended for new designs. Existing customers should contact their <a href=\"https:\/\/kinet-ic.com\/cn\/contact-us\/#sales\">local sales office<\/a> for more information.<\/p>\n\t    <a href=\"https:\/\/kinet-ic.com\/wp-content\/uploads\/2026\/06\/AS1602_typ_app_dia.png\" class=\"gallery-image\" data-elementor-open-lightbox=\"yes\"\n   data-elementor-lightbox-slideshow=\"0\">\n\t\t\t<img decoding=\"async\" src=\"https:\/\/kinet-ic.com\/wp-content\/uploads\/2026\/06\/AS1602_typ_app_dia.png\" alt=\"\" \/>\n\t\t<\/a>\n\t\t    <a href=\"https:\/\/kinet-ic.com\/wp-content\/uploads\/2026\/06\/AS1602_typ_app_dia1.png\" class=\"gallery-image\" data-elementor-open-lightbox=\"yes\"\n   data-elementor-lightbox-slideshow=\"0\">\n\t\t\t<img decoding=\"async\" src=\"https:\/\/kinet-ic.com\/wp-content\/uploads\/2026\/06\/AS1602_typ_app_dia1.png\" alt=\"\" \/>\n\t\t<\/a>\n\t<p><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div id=\"tab-2550272312\" class=\"tab-pane fade\">\n\t\t\t\t\t\t\t<ul>\n<li>Enables system designers to comply with:\n<ul>\n<li>CISPR22 and FCC Part 15, Class B requirements for Radiated and Conducted Emissions<\/li>\n<li>IEC 61000-4-3 requirements for Radiated and Conducted Immunity, Level 3 or higher<\/li>\n<li>IEC 61000-4-2 ESD (Air Discharge) of \u00b125kV<\/li>\n<li>IEC 61000-4-2 ESD (Contact Discharge) of \u00b112kV<\/li>\n<li>Cable Discharge Event (CDE) of \u00b112kV<\/li>\n<\/ul>\n<\/li>\n<li>Provides up to 10dB of additional common mode noise suppression over the frequency of 1MHz to 125MHz when used with Ethernet magnetics<\/li>\n<li>Robust built-in ESD suppressors protect the Ethernet PHY and improve system ESD performance<\/li>\n<li>JESD22-A114, ESD, HBM of \u00b18kV<\/li>\n<li>Interfaces to standard Ethernet transformers and 10\/100\/1000 Ethernet PHYs<\/li>\n<li>Uses a single standard power rail (3.3V or 2.5V)<\/li>\n<li>Open drain output stage that can be biased from 1.8V to 3.3V using transformer center-tap supply as needed based on choice of Ethernet PHY<\/li>\n<li>Flow-through routing for ease of board layout<\/li>\n<li>Typical power consumption of 90mW<\/li>\n<li>Low power mode available<\/li>\n<li>Industrial temperature range (-40\u00b0C to +85\u00b0C)<\/li>\n<\/ul>\n<p><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div id=\"tab-2550272313\" class=\"tab-pane fade\">\n\t\t\t\t\t\t\t<ul>\n<li>Ethernet systems requiring additional CM suppression to meet EMC Class B emissions or higher EMI immunity requirements and ESD protection<\/li>\n<li>POE and Non-PoE Ethernet systems<\/li>\n<li>VoIP Phones, IP Cameras, WAPs, Routers, Switches<\/li>\n<li>Set Top Boxes, Networked Printers and Appliances, Desktop and Laptop Computers<\/li>\n<\/ul>\n<p><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div id=\"tab-2550272314\" class=\"tab-pane fade\">\n\t\t\t\t\t\t\t<table class=\"tbl-product__table\">\n<thead>\n<tr>\n<td><strong>Vin(Min)<\/strong><\/td>\n<td><strong>Vin(Max)<\/strong><\/td>\n<td><strong>CISPR22 and FCC Part 15<\/strong><\/td>\n<td><strong>IEC 61000-4-3 requirements for Radiated and<\/strong><br \/>\n<strong>Conducted Immunity<\/strong><\/td>\n<td><strong>IEC 61000-4-2 \u9759\u7535\u653e\u7535\uff08\u7a7a\u6c14\u653e\u7535\uff09<\/strong><\/td>\n<td><strong>IEC 61000-4-2 \u9759\u7535\u653e\u7535\uff08\u63a5\u89e6\u653e\u7535\uff09<\/strong><\/td>\n<td><strong>Cable Discharge Event (CDE)<\/strong><\/td>\n<td><strong>\u5305<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>2.17V or 3.13V<\/td>\n<td>2.63V or 3.47V<\/td>\n<td>\u00a0Class B, for Radiated and Conducted Emissions<\/td>\n<td>Level 3 or higher<\/td>\n<td>\u00b125kV<\/td>\n<td>\u00b112kV<\/td>\n<td>\u00b112kV<\/td>\n<td>QSOP-16L (SOIC narrow)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Description Features Applications Parameters Enables system designers to comply with: CISPR22 and FCC Part 15, Class B requirements for Radiated and Conducted Emissions IEC 61000-4-3 requirements for Radiated and Conducted Immunity, Level 3 or higher IEC 61000-4-2 ESD (Air Discharge) of \u00b125kV IEC 61000-4-2 ESD (Contact Discharge) of \u00b112kV Cable Discharge Event (CDE) of \u00b112kV [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":16299,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-product.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-295","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/pages\/295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/comments?post=295"}],"version-history":[{"count":10,"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/pages\/295\/revisions"}],"predecessor-version":[{"id":23576,"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/pages\/295\/revisions\/23576"}],"up":[{"embeddable":true,"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/pages\/16299"}],"wp:attachment":[{"href":"https:\/\/kinet-ic.com\/cn\/wp-json\/wp\/v2\/media?parent=295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}